OTT System Aeration Equipment Oxygen Transfer Tests - Supplier in Malaysia - Semenyih Area - Kuala Lumpur - Selangor

5. Test Data And Results

The following tables include basic test conditions and results for the 5 test runs conducted. Detailed listing of full test data and conditions, together with individual probe C* and Kla values, both in test and standard conditions, for each probe and test run are included in Annex 2.

TABLE: TEST CONDITIONS AND RESULTS

TEST

DATE

W. TEMP. 

(ºC)

AIRFLOW

       (Nm3/h)

AIRFLOW

       (SCFM)

SOTE (%)

FP1.56R1

5/12

9.2

111.31

70.32

34.66

FP1.56R2

12/12

9.2

111.52

70.44

36.60

FP1.56R3

12/12

9.3

112.48

71,05

36.53

FP3.28

5/12

9.4

236.94

149.68

33.93

FP5.93

5/12

9.6

428.95

270.97

32.52





For more information or enquiry, please contact Environmech Sdn. Bhd.