Technical Data for Electromagnetic Flow Meter
Measuring accuracy
Reference conditions | Flow conditions similar to EN 29104 |
Medium : Water | |
Electrical conductivity: ≥300µs/cm | |
Temperature: +10…+30ºC (+50ºF…+86ºF) | |
Inlet section : ≥5DN | |
Operating pressure : 1bar (14.5 psig) | |
Flow Meter Accuracy | Standard : ±0.5% of rate |
Optional : ±0.2% of rate |
For more information or enquiry, please contact Environmech Sdn. Bhd.