Initial Operation for CAF-700 & CAF-7500 Series Electric Self-Cleaning Screen Filter supplier in Selangor Area


Initial Operation
1. Gradually open the inlet valve (make sure that the outlet valve, if installed, is open).

WARNING
Take precautions while operating the filter because the filter might enter a flushing
mode automatically, without prior warning.
2. Check the filter assembly and its connections for leaks.
3. Perform a flushing cycle by disconnecting the high pressure tube from the differential
pressure indicator (closing of the electrical circuit) – re-connect it immediately as flushing
starts.
4. Verify that the motor starts spinning clockwise (if the motor spins to the opposite side,
change the connections of the electric phase) and stop after 10 seconds.
5. Verify that the hydraulic flushing valve opens and closes after 10 seconds.
6. Perform a flushing cycle by pressing the MANUAL FLUSH switches at the control
panel.
7. Perform continues flushing by disconnecting the high-pressure tube from the
differential pressure indicator (closing of the electrical circuit) second flushing will start
without a delay. Re-connect the high pressure tube.
8. When the filter is clean, verify that the differential pressure between inlet and outlet
does not exceed 0.1 bar.
9. Set the appropriate differential pressure for flushing at the ΔP differential pressure
indicator to 0.5 bar (7 psi).

For more information or enquiry, please contact Environmech Sdn. Bhd.
Contact us: http://www.environmech.com/p/contact-us.html 

Website: www.Environmech.com